Analysis of the lighting system and its effect on lighting comfort in a basic commodities wholesale company

Authors

DOI:

https://doi.org/10.70577/asce.v5i3.1016

Keywords:

Work environment, lighting, safety measure.

Abstract

A deficient lighting system in the work environment has a significant impact on the productivity and physical and mental health of workers, so this research analysed the impact of lighting on lighting comfort in the logistics area of a marketing company of basic necessities. The main objective was to evaluate the relationship between illuminance levels and the working comfort of exposed personnel. The methodology used a quantitative, correlational and field approach, by measuring lighting levels with the luxmeter in the warehouse area of the marketer, the application of the light comfort questionnaire was applied to a sample of 19 workers and computational modeling in the DIALux EVO 13 software. The statistical analysis, using Pearson's correlation coefficient, yielded a value of -0.9517, which shows a strong negative correlation: the higher the level of lighting (lux), the lower the feeling of discomfort reported, the measurements carried out yielded an average value of 297.65 lux, close to the reference values established in the applicable regulations for this type of spaces (300 lux). level to be considered in the prevention of occupational accidents. The simulation of the lighting system that satisfies the requirements of the process and related regulations; It allowed the type of luminaires and the willingness to be used to be used for optimal use of resources, with an improvement in lighting comfort and a decrease in occupational accidents and improvements in productivity.

Downloads

Download data is not yet available.

References

Arias Carrera, R., & Palacios Carrera, T. (2025). Análisis del ruido, iluminación e Indice de peligrosidad en el manejo de agentes químicos en talleres de la Facultad de Artes. FIGEMPA: Investigación Y Desarrollo, 20(2). https://doi.org/https://doi.org/10.29166/revfig.v20i2.7720 DOI: https://doi.org/10.29166/revfig.v20i2.7720

Baraza Sánchez, X., Castejón Vilella, E., & Guardino Solá, X. (2014). Higiene Industrial. UOC.

Briceño Ayala, L. (2022). Medicina preventiva, ocupacional y ambiental. Manual Moderno.

Cabascango Camuendo, C. P., Luis Mauricio , S. C., & Campoverde Campoverde, D. O. (2021). Análisis de la iluminación general y su incidencia en la ergonomía visual. Revista Cuatrimestral “Conecta Libertad”, 5(2), 34 - 47.

Cabrera Armijos, R. A., Oñate Haro, C. A., Echeverría Carrera, C. A., & Berríos Rivas, A. T. (2024). Evaluación integral de riesgos laborales: posturas forzadas, contaminación auditiva e iluminación en entornos de trabajo, estudios de casos reales. Quito, Ecuador: Religación Press. https://elibro.net/es/ereader/uteq/281595 DOI: https://doi.org/10.46652/ReligacionPress.196

Cienfuegos Gayo, S., & Millas Alonso, Y. (2019). Seguridad y Salud en el Trabajo para PYMES según la Norma ISO 45001:2018. AENOR.

de la Cruz Chaidez, M. T., Armendariz López, J. F., Martín del Campo Saray, F. J., Sahagún Valenzuela, M. I., Castañón Bautista, M. C., & García Gómez, C. (2022). Evaluación del confort térmico y lumínico en aulas universitarias en Tijuana, Baja California. Caso de estudio FCITEC, Valle de las Palmas. Revista de Ciencias Tecnológicas (RECIT), 5(4), 419 - 452. https://doi.org/https://doi.org/10.37636/recit.v54419452 DOI: https://doi.org/10.37636/recit.v54419452

Frías Navarro, D. (2025). Apuntes de estimación de la fiabilidad de consistencia interna de los ítems de un instrumento de medida. España: Universidad de Valencia. https://www.uv.es/friasnav/AlfaCronbach.pdf

García Fernández, J., & Boix Aragonés, O. (2004). Luminotecnia. Iluminación de interiores y exteriores. Departamento de Ingeniería Eléctrica de Catalunya. Retrieved 21 de 06 de 2026, from https://recursos.citcea.upc.edu/llum/interior/iluint2.html

Henao Robledo, F. (2014). Riesgos Físicos II: Iluminación (2da. ed. ed.). Bogotá: Ecoe Ediciones.

Ministerio de Trabajo y Economía Social. (s.f.). Evaluación y y acondicionamiento de la iluminación en puestos de trabajo. Instituto Nacional de Seguridad y Salud en el Trabajo. https://www.insst.es/documents/94886/591747/CUEST+C003+Evaluaci%C3%B3n+y+acondicionamiento+de+la+iluminaci%C3%B3n+en+puestos+de+trabajo.pdf/c8905fca-b396-4b51-a27d-d63591f268a9?t=1583253264421

Muñoz Paredes, C. C., & Mariño Andrade, H. G. (2025). Evaluación del impacto de los niveles de iluminación en la salud ocupacional en las áreas de trabajo de Exportquil S.A. en Guayaquil, 2024. RELIGACIÓN, 10(47). https://doi.org/http://doi.org/10.46652/rgn.v10i47.1550 DOI: https://doi.org/10.46652/rgn.v10i47.1550

Obregón Sánchez, M. G., & Francisco Márquez, M. (2018). Impacto Del Factor Iluminación Y Psicosocial En El Desempeño Laboral Del Personal De Apoyo Y. European Scientific Journal, 14(4). https://doi.org/https://doi.org/10.19044/esj.2018.v14n4p223 DOI: https://doi.org/10.19044/esj.2018.v14n4p223

Olivo Vidal, D. J., Trujillo Ronquillo, D. F., & Morales Tamayo, Y. (2025). Estudio comparativo de la eficiencia de las tecnologías. Nexus, 4(1). https://doi.org/https://doi.org/10.62943/nrj.v4n1.2025.166 DOI: https://doi.org/10.62943/nrj.v4n1.2025.166

Pacheco Ochoa, V., Jiménez Pérez, A. L., & Ramírez Pérez, J. F. (2021). Impacto de la luz y la ventilación natural en el ambiente. UNESUM-Ciencias: Revista Científica Multidisciplinaria, 5(4), 97 - 108. DOI: https://doi.org/10.47230/unesum-ciencias.v5.n4.2021.581

Presidencia de la República del Ecuador. (02 de 05 de 2024). Reglamento de Seguridad y Salud en el Trabajo (Decreto Ejecutivo 255). www.trabajo.gob.ec: https://www.trabajo.gob.ec/wp-content/uploads/2024/01/DECRETO-EJECUTIVO-255-REGLAMENTO-DE-SEGURIDAD-Y-SALUD-DE-LOS-TRABAJADORES.pdf

Quinto Vélez, B. J. (2024). Evaluación de la Iluminación en las áreas de trabajo del personal de Salud de una institución pública, período enero-junio 2023. (Tesis de Maestría). Universidad Técnica del Norte, Ibarra. https://files01.core.ac.uk/download/pdf/619882349.pdf

Sanchez Sanaguano, F. G. (2023). Niveles de iluminación y su relación con la afectación visual en los empleados de una empresa, en Machachi—Ecuador. (Tesis de Maestría). Universidad Regional Autónomo de los Andes, Ambato. https://dspace.uniandes.edu.ec/handle/123456789/16811

Velazco Yañez, C. A. (2022). Eficacia de la implementación de un sistema de control de iluminación para mejorar el confort visual de los trabajadores del laboratorio de procesamiento de muestras HNCASE - ESSALUD, Arequipa—2022. (Tesis de Maestría). Universidad Tecnológica del Perú, Arequipa, Perú. https://repositorio.utp.edu.pe/item/6f871302-ee7c-4a6d-ab4c-f4441ab81a1d

Published

2026-07-17

How to Cite

Mancheno Padilla , E. M., García Arias , F. R., Guamán Guamán, A. L., & Jarrín Cedeño, J. A. (2026). Analysis of the lighting system and its effect on lighting comfort in a basic commodities wholesale company. ANNALS SCIENTIFIC EVOLUTION, 5(3), 840–856. https://doi.org/10.70577/asce.v5i3.1016

Similar Articles

1 2 3 4 5 6 7 8 9 10 > >> 

You may also start an advanced similarity search for this article.