Study of the Trunk Line of Rural Feeders No. 2 from Substations 08 and 13 of Empresa Eléctrica Riobamba S.A. to Establish Redundancy Points and Technical Service Quality Optimization
DOI:
https://doi.org/10.70577/asce.v5i3.1072Keywords:
Electrical Network, Power Distribution, Service Quality, Reliability, Voltage.Abstract
In rural feeders No. 2 of substations 08 (Guamote) and 13 (Pungalá) belonging to Empresa Eléctrica Riobamba S.A., the radial topology and difficult geographical access caused non-compliant voltage drops and prolonged service restoration times, which evidenced the need to optimize the distribution network. To address this problem, applied research with a quantitative and experimental simulation design was carried out. The methodology first comprised a baseline diagnosis from GIS records and load profile histories modeled in CYMDIST software. Second, the physical reconfiguration and conductor cross-section upgrade of the main trunk line toward accessible roads were designed, coupling a three-phase open-loop interconnection recloser as a redundancy point. Finally, the validation of power flow and voltage regulation was verified in the ETAP platform. The simulated results demonstrated that the proposal reduced the maximum voltage drop from 6.00% to 2.09%, and decreased the Total Interruption Time index (TTIK) from 52.23 h to 11.65 h in the Guamote feeder, and from 28.85 h to 11.59 h in the Pungalá feeder. In conclusion, the proposed reconfiguration resolved the technical bottlenecks of the rural network and ensured compliance with the regulatory limits established by ARCERNNR.
Downloads
References
Agencia de Regulación y Control de la Energía y Recursos Naturales No Renovables. (2020).
Regulación ARCERNNR 002/20: Calidad del servicio de distribución y comercialización de energía eléctrica. ARCERNNR. https://www.controlrecursosyenergia.gob.ec/
CYME International T&D. (2021). CYMDIST: Distribution system analysis software (Version
9.0) [Manual de software]. CYME International T&D. https://www.cyme.com/software/cymdist/
Empresa Eléctrica Riobamba S.A. (2022). Plan estratégico institucional e índices de
confiabilidad del sistema de distribución. EERSA. https://www.eersa.com.ec/
Empresa Eléctrica Riobamba S.A. (2024). Informe técnico anual de índices de calidad y
confiabilidad del sistema de distribución. Departamento de Planificación y Geoinformática.
ETAP Operation Technology, Inc. (2022). ETAP power system analysis software - User guide
(Version 21.0) [Manual de software]. ETAP. https://etap.com/
IEEE Power and Energy Society. (2012). IEEE guide for electric power distribution reliability
indices (IEEE Std 1366-2012). IEEE. https://doi.org/10.1109/IEEESTD.2012.6209326
Ley Orgánica del Servicio Público de Energía Eléctrica. (2015). Registro Oficial Suplemento
418 de 16 de enero de 2015. Asamblea Nacional del Ecuador.
Mejía Banda, C. D. (2023). Estudio de la troncal de los alimentadores rurales N° 2 de las
Subestaciones 08 y 13 de la Empresa Eléctrica Riobamba S.A. para establecer puntos de redundancia (Trabajo de titulación de grado, Universidad Técnica de Cotopaxi). Repositorio Institucional UTC. http://repositorio.utc.edu.ec/handle/27000/9876
Short, T. A. (2014). Electric power distribution handbook (2nd ed.). CRC Press.
https://doi.org/10.1201/b16521
Willis, H. L. (2004). Power distribution planning reference book (2nd ed.). CRC Press.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2026 César Augusto Taday Álvarez, Carlos Daniel Mejía Banda

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
Eres libre de:
- Compartir : copiar y redistribuir el material en cualquier medio o formato
- Adaptar : remezclar, transformar y desarrollar el material
- El licenciante no puede revocar estas libertades siempre y cuando usted cumpla con los términos de la licencia.
En los siguientes términos:
- Atribución : Debe otorgar el crédito correspondiente , proporcionar un enlace a la licencia e indicar si se realizaron cambios . Puede hacerlo de cualquier manera razonable, pero no de ninguna manera que sugiera que el licenciante lo respalda a usted o a su uso.
- No comercial : no puede utilizar el material con fines comerciales .
- CompartirIgual — Si remezcla, transforma o construye sobre el material, debe distribuir sus contribuciones bajo la misma licencia que el original.
- Sin restricciones adicionales : no puede aplicar términos legales ni medidas tecnológicas que restrinjan legalmente a otros hacer algo que la licencia permite.